Senior Living & Care Facilities · Metro Atlanta, GA
Regulatory compliance, operational continuity and verified air quality — delivered with zero disruption to your senior living operation in Metro Atlanta, GA. Certified crews, engineered containment, and a documented report at handover.

Senior living in Metro Atlanta, GA share a specific set of failure modes in their HVAC systems. Below are the four we are called about most, and the standards that govern how each one has to be corrected and documented.
Respiratory-compromised residents react quickly to dust and odor events.
Microbial growth at the coil recirculates odor through an entire wing.
Surveyors cite visible dust at registers and unmaintained air handlers.
Moving residents out of rooms is costly and distressing, so work must stay contained.
| Standard | How it applies |
|---|---|
| IICRC-certified source removal | Verified source removal and post-clean inspection. |
| ASHRAE 62.1 | Ventilation and filtration baseline for residential care occupancies. |
| EPA-registered disinfectants | Labeled products applied with documented dwell times. |
| OSHA 1910 | Technician safety controls in occupied care environments. |
Fire and smoke damper inspection and testing, grease-bearing exhaust cleaning and life-safety documentation prepared for AHJ and insurer review.
Every project follows the same sequence, whether it is one air handler or a full campus. Each step produces evidence that ends up in your handover report.
Every system is filmed before a brush touches it. The baseline footage sets the scope, identifies damage and closed dampers, and becomes the first half of your before/after record.
Work zones are isolated and held under negative pressure with HEPA-filtered machines, so debris leaves through the equipment instead of into the occupied building.
Rotary brushes, air whips and compressed-air tools release bonded debris while the vacuum holds continuous capture — source removal, not surface dusting.
Once the system is physically clean, labeled antimicrobial chemistry is applied to duct interiors, coils and pans, with product, dilution and dwell time logged.
Post-clean camera footage, airflow readings and particle counts are compiled into one report with technician credentials, standards applied and a floor-plan reference.
Rarely. Registers are isolated, negative pressure keeps dust inside the containment, and most rooms are back in normal use the same day. We coordinate the schedule with your nursing team in advance.
Loud extraction is scheduled into daytime activity hours agreed with your team, machines are exhausted away from occupied corridors, and only low-odor labeled chemistry is used.
A dated record identifying each damper or hood by location, the condition found, the corrective action taken, and the technician who performed it. That is exactly the format of the binder we hand over.
It is photographed, logged as a deficiency with its location, and reported to you the same day. Repairs are quoted separately so nothing is done to life-safety equipment without your written approval.
Yes. Most commercial work in Metro Atlanta runs outside normal operating hours. We build the schedule around your occupancy and hand each area back clean and ready for use before your team returns.